5. Connect neutral and earth conductors to neutral stud and earth stud respectively.
6. For all connections ensure conductors are secure and appropriately terminated.
7. Tighten cable gland to secure against tension on cable.
8. Check that polarity of each connection is correct to mains connection terminals markings on
appliance.
NOTE:
This appliance must be earthed.
Fixed wiring installations must incorporate an all-pole disconnection switch.
9. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
10. Connect power supply to the appliance.
11. Check that electrical supply is within input rating specification, refer to Specificationssection).
1. Before leaving a new installation;
a. Check following functions in accordance with operating instructions specified in Operation
section of this manual.
Light the Griddle.
Light the Open Burners. (F - Flame Failure Option).
Light the Open Burners. (PF - Pilot and Flame Failure Option).
Check the Low Fire Burner Operation.
Check the High Fire Burner Operation.
Check the Oven Heating.
Check the Oven Thermostat Operation.
Check the Oven Fan Operation (GEC Models only).
b. Ensure that operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2. This manual must be kept by owner for future reference, and a record of
Date of Purchase,
Date of
Installation
and
Serial Number of Appliance
recorded and kept with this manual.
(These
details can be found on Rating Plate attached to front right hand corner of bottom sill.
Refer to Gas Connectionsection).
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut off gas
supply and contact supplier of this appliance.