27
NOTE: The gas regulator supplied is
convertible between Natural
Gas and LP Gas, but its outlet
pressure is fixed ex-factory
and is NOT to be adjusted.
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Before leaving the installation;
1. Check all gas connections for leakage using soapy water or other gas detecting equipment.
2. Carry out a Commissioningcheck of appliance as shown in Installation Section of this manual.
3. Ensure any paint sealed components are re-sealed on completion of adjustments.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.