- All Other Markets
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to Gas Conversion and Specifications' section in this manual for further details.
Gas supply connection point is located at rear of appliance:-
For GE505 / GE54, located approximately 130 m m from right hand side, 36mm from rear
and 655mm from floor and is reached from beneath appliance.
For GE506 / GE56, located approximately 130 m m from right hand side, 32mm from rear
and 655mm from floor and is reached from beneath appliance.
For GE508 / GE58, located approximately 130 m m from right hand side, 35mm from rear
and 655mm from floor and is reached from beneath appliance.
Connection is ¾" BSP male thread (for all other models).
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See Gas Connectioninformation overleaf.
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa 0.63 kPa
Gas Connection
See Gas Connectioninformation overleaf.