29
- All Other Markets
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Open Burner
Main Burner Ø 2.45mm Ø 4.50mm
Pilot Burner ('PF' Models only) 0.30 0.60
Griddle
Main Burner Ø 2.10mm Ø 3.40mm
Pilot Burner 0.35 0.60
Burner Aeration Setting Fully open Fully open
Supply Pressure 1.13 - 3-4 kPa 0.75 - 1.5 kPa
Burner Operating Pressure (*) 0.95 kPa 0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified)
Open Burner
Main Burner Ø 1.50mm Ø 1.40mm
Pilot Burner ('PF' Models only) 0.20 0.20
Griddle
Main Burner Ø 1.30mm Ø 1.40mm
Pilot Burner 0.23 0.23
Burner Aeration Setting Fully open
Supply Pressure 2.75 - 4.5 kPa
Burner Operating Pressure (*) 2.6 kPa
Gas Regulator Cap Screw