12
Regulator connections are
3
/
4
" BSP female.
Connection to appliance is
3
/
4
" BSP male.
(Refer to Specifications section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
3. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
4. Connect gas supply to appliance. A suitable jointing compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
5. Check all gas connections for leakages using soapy water or other gas detecting equipment.
NOTE: Measure burner operating pressure at manifold test
point with two burners operating at Fullsetting.
6. Check gas operating pressure is as shown in Specifications
section.
7. Verify operating pressure remains correct.
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
Each appliance should be connected to an adequately
protected power supply and an isolation switch mounted
adjacent to, but not behind appliance. This switch must
be clearly marked and readily accessible in case of fire.
1. Check electricity supply is correct as shown on
Rating Plate attached to lower front hand side of
front sill panel.
2. Supply terminal connections are located at rear of
appliance. Refer to Electrical Connectionsin
Dimensionssection of manual.
3. Open oven door and remove oven control panel to
allow connection access for electrical supply.
4. Connect mains supply to L1, L2 and L3 connection
terminals. Refer to 'Electrical Supply
Requirements' section for connection details.
NOTE: This appliance can be converted from 3 Phase to Single Phase supply by connecting single
phase input to L1 and adding a bridge wire between L1, L2 and L3 connections, (refer to Fig
3 above and information shown in 'Electrical Supply Requirements Table' in 'Specifications'
Section).
Fig 2
Manifold Test
Point
Add bridging
wires between
L1, L2 and L3.
Neutral sup-
ply connection
Phase supply
connection to L1
P
N
Fig 3
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
THIS APPLIANCE MUST BE EARTHED. IF SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.