Rinnai 25 ES_FT_OIM
FLUE INSTALLATION
TYPES OF FLUE INSTALLATIONS
Consult the ‘Energysaver Space Heater Co-Axial Flue Systems Installation Manual’ included with
the ‘On Wall’ or ‘Direct’ flue kits for detailed flue installation instructions. Use only Rinnai Flue
components with this appliance.
The following configurations are currently available. For alternative configurations contact Rinnai.
Components
DIRECT / EXTENDED Option A (Direct) Option B (Direct Extended)
Direct Flue Kit ESDFK Direct Flue Kit
Co-Ax Pipe 900mm (Optional) #
ESDFK
ESPIPE900
SIDEWAYS Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Back Cover Set
(see note below)
ESDFK
ESPIPE900
EXTERNAL WALL Components
Option A (Vertical Termination) Option B (On Wall Termination)
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Condensate Trap
Roof Cowl
ESDFK
ESPIPE900
ESBEND
ESCONDK
ESROOFCOWL
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Condensate Trap
ESDFK
ESPIPE900
ESBEND
ESCONDK
IN-WALL Components
Option A (Direct) Option B (Offset)
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
Roof Cowl
ESFKITIW
(ESKIT03)
ESPIPE900
ESROOFCOWL
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Roof Cowl
ESFKITIW
(ESKIT03)
ESPIPE900
ESBEND
ESROOFCOWL
UNDER FLOOR Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Back Cover Set
(see note below)
ESDFK
ESPIPE900
ESBEND
# Order lengths as required
§ Includes Condensate Trap (ESCONDK)
The Energysaver Heater comes supplied with a standard back cover kit. For ‘Sideways’ and
‘Underfloor’ installations, refer to the ‘Energysaver Space Heater Co-Axial Flue System
Installation Manual’ for details of the alternative back cover kit required.
Flue is NOT to be terminated under the floor or in a roof space. ‘Down & Out’ and vertical ‘through
roof’ flue installations are permitted ONLY when the flue terminal is located externally.
For horizontal installations including ‘Down & Out’ flue systems there must be a continuous fall of
at least 2° to the termination point to drain condensate.
Flue terminal must be at least 300 mm above the ground in accordance with AS/NZS 5601, Clause
6.9 and Fig. 6.2.
All terminations exceeding a vertical height of 1.5 metres must incorporate a condensate trap.
The ‘AIR INTAKE’ hose MUST NOT BE CUT OR SHORTENED. For more detailed information refer
to ‘Energysaver Space Heater Co-Axial Flue Systems Installation Manual’.
I M PORT A N T
N OT E
DO N OT
WARN I N G