7
Model
Power Supply
Total Power
Input
Amps
Voltage Type Frequency
L1 L2 L3
IN511R3 230-240 Vac 1P+N+E 50 / 60 Hz 3.5 kW 15.2 n/a n/a
IN511R5 400-415 Vac 3P+E 50 / 60 Hz 5.0 kW 7.2 7.2 7.2
IN511F 400-415 Vac 3P+E 50 / 60 Hz 5.0 kW 7.2 7.2 7.2
IN512R3 400-415 Vac 3P+E 50 / 60 Hz 7.0 kW 10.2 10.2 10.2
IN512R5 400-415 Vac 3P+E 50 / 60 Hz 10 kW 14.5 14.5 14.5
IN512F 400-415 Vac 3P+E 50 / 60 Hz 10 kW 14.5 14.5 14.5
IN514R3 400-415 Vac 3P+E 50 / 60 Hz 14 kW 21 21 21
IN514R3F 400-415 Vac 3P+E 50 / 60 Hz 17 kW 24.6 24.6 24.6
IN514R5 400-415 Vac 3P+E 50 / 60 Hz 20 kW 29 29 29
IN514R5F 400-415 Vac 3P+E 50 / 60 Hz 20 kW 29 29 29
IN514F 400-415 Vac 3P+E 50 / 60 Hz 20 kW 29 29 29
Installation must be carried out by registered installation contractors only.
The contractors are responsible for interpreting all instructions correctly and performing the installation in
compliance with all applicable national and local regulations.
The warning signs and serial plates on the equipment must strictly be followed.
The device must be protected and connected with an all-pole circuit breaker which ensures complete
separation under overvoltage category III.
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.
The device must be operated with an all-pole circuit breaker or dis-connector of overvoltage category III.
CE Induction Appliance only: If ground fault current protective sw itches are used, they must
be designed for a minimum fault current of 30mA, Type B or B+.
Notice
Ensure the supply voltage and the line current match the specifications given on the serial plate affixed to
the appliance. Wrong voltage will damage the appliance. A stable power supply must be provided.
Notice
Always refer to the serial plate on the appliance to verify the electrical data. When the data listed on the
serial plate is different than that listed in this manual, contact the manufacturer or the authorized
representative.
Notice
All cables must be routed, protected and tension free.