Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch must be clearly marked and readily accessible in
case of fire.
1. Check that the electricity supply is correct as shown on the Rating Plate. Refer to the section 3
(Dimensions) for rating plate locations for the different model types.
2. The supply terminal connections are located at the rear of the the appliance. Refer to Electrical
Connectionsin the section 2 (Specifications) of the manual.
3. Bring the supply cable up through the compression type gland provided on the rear of the main
electrical switchgear panel.
4. Connect the mains supply to L1, L2 and L3 terminal connections as required. Refer to the Electrical
Supply Requirements in section 2 (Specifications).
5. Connect earth conductors to earth terminal.
6. For all connections ensure that conductors are secure and appropriately terminated.
7. Tighten the cable gland to secure against tension on the cable.
8. Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
9. Connect the power supply to the appliance.
10. Check that the electrical supply is as shown in section 2 (Specifications).
This appliance must be earthed. If the supply cord is damaged, it must be replaced by a suitably qualified
person in order to avoid a hazard.
Notice
ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
Notice
This appliance must be earthed.
Fixed wiring installations must incorporate an all-pole disconnection switch.