NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. The following minimum installation clearances are to be adhered to:
G55T model only
This model is delivered completely assembled. No further assembly is required.
NOTE:
This appliance is fitted with adjustable feet to enable appliance to be positioned securely
and level. This should be carried out on completion of the gas connection. Refer to 'Gas
Connection' section below.
Optional Accessories (Refer to Replacement Parts List)
Plinth Kit. For installation details, refer to instructions supplied with each kit.
1. Check all feet (castors) are securely fitted.
2. Adjust feet to make gas griddle toaster steady and level.
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
1. Blue Seal Gas Griddle Toasters do not require an electrical connection, as they function totally on the
gas supply only.
2. It is essential that gas supply is correct for appliance being installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:
a. Gas Type the appliance has been supplied for, is shown on
a coloured sticker located above gas connection and on
rating plate. Check this is correct for gas supply appliance is
being installed for. Gas conversion procedure is detailed in
this manual.
b. Supply Pressure required for this appliance is show n
in SpecificationsSection of this manual. Check gas supply
to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on Rating Plate and in
Specificationssection of this manual. Input rate should be
checked against available supply line capacity. Particular
note should be taken if appliance is being added to an
existing installation.
NOTE: It is important that adequately sized piping runs directly
to connection joint on griddle toaster with as few tees and
elbows as possible to give maximum supply volume.
3. Fit gas regulator supplied, into gas supply line as close to appliance
as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as shown in Gas Conversion Sectionin this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and
it is NOT to be adjusted.
Regulator connections are
1
/
2
" BSP female.
Connection to appliance is
1
/
2
" BSP male.
(Refer to Specifications section for gas supply location dimensions).
Rating Plate
Fig 1
Left / Right hand side 50mm 0mm
Rear 50mm 0mm