Loading ...
Loading ...
Loading ...
8
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
4. Correctly locate griddle toaster into its final operating position and using a spirit level, adjust legs so
that appliance is level and at the correct height.
5. Connect gas supply to appliance. A suitable jointing compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check gas operating pressure is as shown in Specificationssection.
NOTE: Operating pressure to be measured at
manifold pressure test point and with all
burners operating at High Flamesetting.
8. Verify operating pressure remains correct.
1. Before leaving new installation;
a. Check the following functions in accordance with operating instructions specified in Operation
section of this manual.
Light the Pilot Burner.
Light the Main Burners.
Check the Low Fire burner operation.
Check the High Fire burner operation.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2. This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Appliance
recorded and kept w ith this manual.
(These details can be found on Rating Plate attached to R/H inner side panel (refer to
Gas Connectionsection).
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut Off gas
supply and contact supplier of this appliance.
Pressure Test Point
Low Fire Adjustment
Fig 2
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.