- All Other Markets:
(*) NOTE:
Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
655mm from floor and is entered from beneath appliance. An optional underside connection is
available.
Input Rating (N.H.G.C.) 43MJ/hr 42MJ/hr
Supply Pressure 1.13 - 3.40kPa 0.75 - 1.50kPa
Burner Operating Pressure (*) 1.0kPa 0.63kPa
Gas Connection
1
/
2
BSP Male
Input Rating (N.H.G.C.) 42MJ/hr 42MJ/hr
Supply Pressure 2.75 - 4.50kPa 2.75 - 4.50kPa
Burner Operating Pressure (*) 2.5kPa 2.5kPa
Gas Connection
1
/
2
BSP Male