Loading ...
Loading ...
Loading ...
6
NOTE:
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local, gas, health and safety requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, appliance is
installed in.
Blue Seal Griddle Toasters are designed to provide years of satisfactory service and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
AUSTRALIA: - AS5601 - Gas Installations.
NEW ZEALAND: - NZS5261 - Gas Installation.
UNITED KINGDOM: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 - 1 & 2 Installation Flueing & Ventilation.
IRELAND: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to relevant codes and manufacturers specifications shown in this section will void
the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer, are only to be
adjusted by a qualified service person. They are not to be adjusted by the installation person.
Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate located on R/H inner side panel.
Check the following parts have been supplied with appliance:
Enamelled Crumb Tray 1
Toasting Rack 1
Toasting Rack Tray (St/Steel) 1
Grease Drawer 1
Adjustable Legs 4
Gas Regulator 1
Alternate Gas Conversion Kit 1
1. Installation must allow for sufficient flow of fresh air for combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Position appliance in its approximate working position.
4. All air for burner combustion is supplied from beneath appliance. Legs must always be fitted and no
obstructions placed beneath or around base of appliance, as obstructions will cause incorrect
operation and / or failure of appliance.
5. Components having adjustments protected (e.g. paint sealed) by manufacturer are only allowed to
be adjusted by an Qualified service agent. They are not to be adjusted by the installation person.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to
the appliance flue outlet.
Combustion Air Requirements:
Natural Gas (G20) 10 m
3
/hr
LPG (G31) 9 m
3
/hr
Town Gas 10 m
3
/hr
Loading ...
Loading ...
Loading ...