- All Other Markets:
(*) NOTE:
Measure Burner operating pressure at manifold test point with both burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gasses, if required.
TOWN GAS Only -Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to the details in this section for further details.
Main Burner Injectors Ø 2.10mm Ø 3.80mm
Pilot Burner Injectors 0.35 0.60
Low Fire Adjustment
1 turn out (ccw) 2 turns out (ccw)
Burner Operating Pressure (*) 1.0kPa 0.63kPa
Main Burner Aeration Shutter Fully Open Fully Open
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner
Operating Pressure)
Main Burner Injectors Ø 1.30mm Ø 1.20mm
Pilot Burner Injectors 0.23 0.23
Low Fire Adjustment
½ turn out (ccw) ½ turn out (ccw)
Burner Operating Pressure (*) 2.5kPa 2.5kPa
Main Burner Aeration Shutter Fully Open Fully Open
Gas Regulator Cap Screw