- Australia:
- New Zealand:
- UK Only
Category: II
2H3P
(20, 30 / 37).
Flue Type: A
1.
NOTE:
* - Measure burner operating pressure at manifold test point with both burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart
from when carrying out Gas Conversion, if required. (Refer to Gas Conversionsection for details).
Main Burner Injector 2.10mm 1.30mm
Pilot Burner Injector 0.35mm 0.23mm
Low Fire Adjustment 1 turn out (c.c.w.)
½ turn out (c.c.w.)
Burner Operating Pressure (*) 1.0 kPa 2.5 kPa
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Aeration Gap 15mm (Open) 15mm (Open)
Gas Regulator Cap Screw
Main Burner Injectors 2.10mm 1.30mm
Pilot Burner Injectors 0.35mm 0.23mm
Low Fire Adjustment
turn out (c.c.w.)
½ turn out (c.c.w.)
Burner Operating Pressure (*)
10 mbar 26 mbar
Supply Pressure 20 mbar 37 mbar
Burner Aeration Gap 15mm (Open) 15mm (Open)
Gas Regulator Cap Screw
Main Burner Injector 2.10mm 1.30mm
Pilot Burner Injector 0.35mm 0.23mm
Low Fire Adjustment 1 turn out (c.c.w.)
½ turn out (c.c.w.)
Burner Operating Pressure (*) 1.0 kPa 2.5 kPa
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Aeration Gap 15mm (Open) 15mm (Open)
Gas Regulator Cap Screw