Network Camera User Manual
41
that goes across the pre-defined region. Sensitivity = 100 - S1/ST ×
100. S1 stands for the target body part that goes across the
pre-defined region. ST stands for the complete target body. The
higher the value of sensitivity is, the more easily the alarm can be
triggered.
Figure 6-6 Set Rule
6. Optional: You can set the parameters of multiple areas by repeating the above steps.
7. For the arming schedule settings, refer to Set Arming Schedule. For the linkage method settings,
refer to Linkage Method Settings.
8. Click Save.
6.2.6 Set Unattended Baggage Detection
It is used to detect the objects left over in the pre-defined region. Linkage methods can be
triggered after the object is left and stays in the region for a set time period.
Steps
1. Go to Configuration Event Smart Event Unattended Baggage Detection.
2. Select Channel No.
3. Check Enable.
4. Select one Region. For the detection region settings, refer to Draw Area.
5. Set rules.
Sensitivity
Sensitivity stands for the percentage of the body part of an
acceptable target that enters the pre-defined region. Sensitivity = 100
- S1/ST × 100. S1 stands for the target body part that goes across the
Loading ...
Loading ...