PREINSTALLATION REQUIREMENTS
Electrical System
Requirements
NOTE
Because of potentially inconsistent voltage
capabilities, the use of this laundry center
with power created by gas powered
generators, solar powered generators,
wind powered generators or any other
generator other than the local utility
company is not recommended.
Electrical Requirements for
Electric Dryer:
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or
circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT
operate washer and dryer on same circuit.
POWER SUPPLY - 3-wire or 4-wire, 120/240
volt, single phase, 60 Hz, Alternating
Current.
NOTE
A 120/208 volt, single phase, 60 Hz,
Alternating Current supply may be used on
dryers marked for use on rating plate.
NOTE
The electric laundry center has been
designed and certified to operate at both
240V and 208V. Drying times on a 208V
power supply will, however, be approximately
20% longer than drying times on a 240V
power supply. This is normal and expected
behavior and applies to all drying cycles.
IMPORTANT
The laundry center is internally grounded
to neutral unless it was manufactured for
sale in Canada.
Only a 4-conductor cord shall be used
when the appliance is installed in a
location where grounding through the
neutral conductor is prohibited. Grounding
through the neutral link is prohibited for: (1)
new branch circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4)
areas where local codes DO NOT permit
grounding through the neutral.
3-wire Power Supply Cord (not
supplied)
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type SRDT
rated at 240 volt AC minimum,
30 amp, with 3 open end spade lug
connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see “Electrical connection
(non-Canada) - 3-wire cord” in Electrical
Installation section.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the
laundry center is in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
3-wire receptacle
(NEMA type 10-30R)
4-wire Power Supply Cord
(not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type SRDT
or DRT (as required) rated at 240 volt AC
minimum, 30 amp, with 4 open end spade
lug connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 4-wire cord connection
instructions see “Electrical connection
(non-Canada) - 4-wire cord” in Electrical
Installation section.
WARNING
FIRE HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
DO NOT install a booster fan in dryer
exhaust duct.
Install all laundry centers in accordance
with the installation instructions in this
manual.