LG Electronics LQN120HV4 LG Air Conditioner Cooling Area, Adjustable Air Direction

User Manual - Page 87

For LQN120HV4.

PDF File Manual, 243 pages, Read Online | Download pdf file

LQN120HV4 photo
Loading ...
Loading ...
Loading ...
STD. WALL-MOUNTED | 87
Low Wall Console
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F
Selecting Pipe Routing
The pipe can be routed in one of six directions as shown in Figure 108.
Figure 108:Pipe Holes and Routing.
3
1
2
6
5
4
Pipe Guide
Pipe Guide
Connecting Pipe must be placed
inside to the pipe guide.
Connecting
Pipe
Connecting
Pipe
[Unit : inch (mm)]
1-25/32 (45)
3-17/32 (90)
2-15/16 (75)
Left bottom piping
Right bottom piping
Left/right piping
Right back piping
2-3/8 (60)
1-9/16 (40)
1-31/32 (50)
Wall
3-17/32 (90)
2-15/16 (75)
Left back piping
Right back piping
1-25/32 (45)
1-25/32 (45)
Pipe Connection
Connect the pipes as shown in Figure 109
1. Hold up the Sensor Link.
2. Separate the Pipe Bracket (2 screws)
3. Connect the refrigerant pipe. (Refer to next page)
4. Assemble the Pipe Bracket (2 screws)
5. Put down the Sensor Link.
Figure 109:Pipe Connection.
21
54
3
Loading ...
Loading ...