2.6.2 CENTRAL HEATING SYSTEM (NZ62CH)
May be used to heat rooms up to 50 feet (15.2m) from the appliance. A wall mounted thermostat located in the room
to be heated controls the blower supplying warm air from the room containing the appliance. Consult with a heating
specialist to ensure a proper duct layout for your home. If the NZ62CH is installed at the bottom of the appliance, it
could introduce a cool draft into the room that the appliance is installed in. When attached to the top or sides of the
appliance, it provides a higher heat output. This option may not be used in mobile homes.
2.6.3 BLOWER CIRCULATION (NZ64)
The NZ64 provides an ideal means of circulating warm air within the room it resides.
The blower will only operate when the doors are fully closed.
We recommend installing the blower in a different room or even a different level of the
house. This will generate greater air movement and improve the distribution of the
warm air coming from the appliance as well as improving air movement in the sum-
mer months if using the summer by pass switch option.
These options may be incorporated with one another. If the optional blower is to be in-
stalled, make provision during framing to route a 110 volt power line to the appliance.
Detailed installation instructions are included with each venting kit.
ATTIC
BLOWER
LOCATION
OPTIONS
NZ3000 H
BLOWER
NO
DUCTING
CENTRAL HEATING &
GRAVITY VENT OPTION
CENTRAL HEATING
CENTRAL HEATING
When installed with a masonry chimney, the hot air gravity and central heating system can only be installed off the sides.
*
SIDES
ONLY
*
EXAMPLE OF DEDICATED DUCTING SYSTEM