Napoleon NZ3000H High Country Series Natural Vent Woodburning Fireplace

User Manual - Page 22

For NZ3000H.

PDF File Manual, 128 pages, Read Online | Download pdf file

NZ3000H photo
Loading ...
Loading ...
Loading ...
W415-1517 / A / 09.02.16
22
EN
6.0 FINISHING
40"
(1016MM)
55 1/2"
(1410MM)
7 3/4" (197MM) MIN CEMENT
BOARD FROM THE SIDE OF
THE UNIT TO COMBUSTIBLES
7 3/4"
(197MM)
MIN
DRYWALL
NON-COMBUSTIBLE
MATERIAL
FACE MUST
HAVE A
MINIMUM
84"(2134MM)
HEIGHT OF
CEMENT BOARD
DEPENDING
UPON CEILING
HEIGHT
COMBUSTIBLE
FACING AND
WOOD FRAMING
MAY START AT
84"(2134MM)
ABOVE THE
BASE OF THE
UNIT
EMBER STRIP
NOTE: JOINT
COMPOUNDS AND
TAPES THAT ARE
RESILIENT TO HEAT
AND CRACKING
SHOULD BE USED
WHEN TAPING AND
MUDDING SEAMS.
!
WARNING
VENTILATION OPENINGS ARE REQUIRED IN ENCLOSURES UP TO 96" HIGH. THEY ARE
RECOMMENDED FOR ALL ENCLOSURES. ABOVE 84" COMBUSTIBLE FINISHING MATERIALS MAY
BE USED ON THE FRONT FACE.
The appliance is shipped with a template that is 1/8" (3.2mm) larger on the
top, bottom and each side than the faceplate. Leave the template in place
when installing the fi nishing material to insure the faceplate will fi t inside the
nishing material edging.
TEMPLATE
USE ONLY A NON-COMBUSTIBLE MATERIAL TO FINISH THE FACE OF THE APPLIANCE. A NON-
COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD IS REQUIRED FOR THIS PURPOSE.
DO NOT INSULATE THE STEEL BODY OF THE APPLIANCE.
NOTE: A ventilated enclosure
is recommended. See
"VENTILATION OPENINGS"
section.
Loading ...
Loading ...
Loading ...