To install properly, please read this "installation manual"
first.
The air conditioner must be installed by qualified persons.
When installing the indoor unit or its tubing, please follow
this manual closely.
If the air conditioner is installed on a metal part of the
building, it must be electrically insulated according to the
relevant standards to electrical appliances.
When all the installation work is finished, please turn on
the power only after a thorough check.
2. INSTALLATION INFORMATION
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes,
lightning rod or a telephone ground wire.Incomplete
grounding may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in
electric shocks.
Connect the outdoor unit wires , then connect the indoor
unit wires.
You should not connect the air conditioner with the power
source until wiring and piping the air conditioner is done.
While following the instructions in this installation
manual, install drain piping in order to ensure proper
drainage and insulate piping in order to prevent
condensation.
Improper drain piping may result in water leakage and
property damage.
Install the indoor and outdoor units, power supply wiring
and connecting wires at least 3.28ft (1m) meter away
from televisions or radios in order to prevent image
interference or noise.
Depending on the radio waves, a distance of 3.28ft (1m) may
not be sufficient enough to eliminate the noise.
The appliance is not intended for use by young children
or infirm persons without supervision.
Don't install the air conditioner in the following
locations:t
Near petroleum facilities.
Near coastal areas with any concentration of salty air.
Near caustic gases, like sulfide, especially when near hot
springs.
The volt vibrates violently (in the factories).
In buses or cabinets.
In kitchens with large amounts of oil gas.
Near a strong electromagnetic wave.
Near inflammable materials or gas.
Anywhere there is acid or alkaline liquid evaporating.
Other hazardous conditions.
If the refrigerant leaks during installation, ventilate the
area immediately.
Toxic gas may be produced if the refrigerant enters into the
area and comes in contact with fire.
The temperature of refrigerant circuit is high, please keep
the interconnection cable away from the copper tube.
After completing the installation work, ensure that the
refrigerant does not leak.
Toxic gas may be produced if the refrigerant leaks into the
room and comes into contact with a source of fire, such as a
fan heater, stove or cooker.
INSTALLATION ORDER
Select the location.
Install the indoor unit.
Install the outdoor unit.
Install the connecting pipe.
Connect the drain pipe.
Connect the wiring.
Test operation.
CAUTION
The appliance must be installed in accordance with
national wiring regulations.
Do not operate your air conditioner in a wet room such
as a bathroom or laundry room.
An all-pole disconnection device which has at least 3mm
clearances in all poles, and has a leakage current that
may exceed 10mA, and a residual current device (RCD)
which has a rated residual operating current not to
exceed 30mA, and a disconnection must be incorporated
in the fixed wiring in accordance with the wiring rules.
5