SAFETY CONSIDERATIONS
Installing, starting up, and servicing air-conditioning equipment
can be hazardous due
to
system pressures, electrical components,
and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should
install, start-up, and service this equipment.
Untrained personnel can perform basic maintenance functions such
as
cleaning coils. All other operations should be performed by
trained service personnel.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.
Follow all safety codes.
Wear
safety glasses and work gloves. Keep
quenching cloth and fire extinguisher nearby when brazing. Use
care in handling, rigging, and setting bulky equipment.
Read these instructions thoroughly and follow all warnings or
cautions included in literature and attached to the unit. Consult
local building codes and National Electrical Code
(NEC) for
special requirements. Recognize safety information. This is the
safety-alert
symbol&.
When you see this symbol on the unit and
in instructions or manuals, be alert
to
the potential for personal
injury. Understand these signal words: DANGER, WARNING, and
CAUTION. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to
identify unsafe practices which
may
result in minor personal
injury or product and property damage. NOTE is used
to
highlight
suggestions which will result in enhanced installation, reliability, or
operation.
A.
WARNING
ELECTRICAL
SHOCK
HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF
position. There may be more than 1 disconnect switch.
Lock out and tag switch with a suitable warning label.
A.
WARNING
EXPLOSION HAZARD
Failure
to
follow this warning could
result in death, serious personal injury,
and/or property damage.
Never use air or gases containing
oxygen for leak testing or operating
refrigerant compressors. Pressurized
mixtures
of
air or gases containing
oxygen can lead
to
an
explosion.
A.
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure
to
follow this caution may result in equipment
damage or improper operation.
Do not bury more than 36 in. (914 mm)
of
refrigerant pipe
in the ground.
If
any section
of
pipe is buried, there must be
a
6 in. (152 mm) vertical rise
to
the valve connections on
the outdoor units.
If
more than the recommended length is
buried, refrigerant may migrate
to
the cooler buried section
during extended periods
of
system shutdown. This causes
refrigerant slugging and could possibly damage the
compressor
at
start-up.
SYSTEM REQUIREMENTS
Allow sufficient space for airflow and servicing unit. See Fig. 1
for minimum required distances between unit and walls or ceilings.
Recommended Connection Method for Power
and
Communi-
cation Wiring
ITo
minimize communication wiring interfer-
ence>
Power Wiring:
The main power is supplied
to
the outdoor unit. The field supplied
connecting cable from the outdoor unit
to
indoor unit consists
of
three (3) wires and provides the power for the indoor unit.
Two
wires are high voltage AC power and one is a ground wire.
Consult your local building codes and the NEC (National
Electrical Code) or CEC (Canadian Electrical Code) for special
requirements.
All wires must be sized per NEC or CEC and local codes. Use
Electrical Data table MCA (minimum circuit amps) and MOCP
(maximum over current protection)
to
correctly size the wires and
the disconnect fuse or breakers respectively.
Per caution note, only copper conductors with a minimum 300 volt
rating and 2/64-inch thick insulation must be used.
Communication Wiring:
A separate shielded copper conductor only, with a minimum 300
volt rating and 2/64-inch thick insulation, must be used
as
the
communication wire from the outdoor unit
to
the indoor unit.
To
minimize voltage drop
of
the control wire, use the following
wire size and maximum lengths shown in the chart below:
Wire Size
Length
ft (m)
18AWG
50 {15)
16AWG
50 {15)
to
100 (30)
A.
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
Wires should be sized based on NEC and local codes.
Use copper conductors only with a minimum 300 volt
rating and 2/64 inch thick insulation.
2