40 Fancircuiterror
50 Wateroutletoverheating
51 Waterinletoverhigh
60 Wateroutlettemperaturecircuitmalfunction
70 Programerror
Note:ifthedisplayederrorisnotlistedabove,immediatelyturnoffthewaterheatercancontactauthorisedservice
centre.
ReplacementParts
Warning!
Alwayscontactaqualified plumber or repairer foranyservicing and repairingjob. Alwayspurchaseoriginal parts
fromONSEN by stating the model number and serial number, specifygastype(LPGorNG),partdescriptionand
numberofpartsdesired.
Formodel:ONHW26NG50/ONHW26LP50/ONHW26NG60/ONHW26LP60
1. Controlboard
2. Gasvalve
3. Burnerassembly
4. Blowermotor
5. Gasmanifold
6. GasinletconnectorR¾
7. Watervalve
8. WaterinletconnectorR¾
9. Strainer
10. HotwateroutletconnectorR¾
11. Remotecontrolterminalblock