Activatingthewaterheater:
o Disconnectthewaterheaterpowerplug.
o TurnthegasservicevalveclockwisetotheOFFposition.Thisvalveislocatedontheoutsideofthe
waterheater.Waitfor5minutestoclearanygas.Ifgascan’tbesmelt,proceedtothenextstep.Ifa
gassmellcanbedetected,STOPandrefertoinstructionsonpage31.
o TurnthegasservicevalvecounterclockwisetotheONposition.
o Reconnectandturnonpowersupplytothewaterheater.Thewaterheaterburnerwill
automaticallylightupwhenthereisademandforhotwater.
WaterTemperature(°C) 2ndDegreeBurn
NoIrreversibleDamage
3rdDegreeBurn
FullThicknessInjury
45 2hours 3hours
47 20minutes 45minutes
48 15minutes 20minutes
50 8minutes 10minutes
55 17seconds 30seconds
60 3seconds 5seconds
Table3
SettingWaterTemperature
Maximum water delivery temperature occurs while the water heater burner is ON. To determine the water
temperature,turnonthewateroutletandplaceathermometertomeasurethewaterstream–seeFigure32.Note:
watertemperatureattheoutletmayvarydependingontheweatherandseasonandthelengthofpipefromthe
waterheater.