TesttheUnit
Purge air andforeignobjectsinthe gas& watersupplylinesbefore connecting the supply lines towater
heater.
TurnthegasandwatersuppliesON.Testforleaks.
Isolate the gas supply. Remove test point screw located at the gas inlet connection and attach pressure
gauge.
Turnonthehotwaterheater&thegassupply.
Ifremotecontrolsarefitted,turntheremotecontrolon.Selectmaximumdeliverytemperatureandopen
ALL availablehot water outlets in the house including the shower.Ifremotecontrolisnotfitted,simply
openallavailablehotwateroutlets.(CAUTION:Ensurebuildingoccupantsdonothaveaccesstohotwater
outletsduringthetest)
Operateallothergasappliancesattheirmaximumgasrate,inaccordingtotheappliancesmanufacturers’
instructions.
Withallgasappliances&hotwaterheateroperatedattheirmaximum gas rate, the gas pressuregauge
shouldreadbetween1.13‐5.0kPaforNaturalGas(NG),andLPGshouldbe2.75–7.0kPa.
Ifpressurereadslower,thegassupplyisinadequateandtheapplianceswillnotperformtospecification.If
istheinstallersresponsibilitytocheckthegasmeter,serviceregulatorandpipeworkforcorrectoperation
&pipesizeandrectifyasrequired.Thegasregulatorinthehotwaterheateriselectronicallycontrolledand
factorypreset,andundernormalcircumstances,DOESNOTneedadjustmentduringinstallation.
Closeallhotwateroutletsincludingtheshower.
Inspectandcleanthestrainerlocatedatthewaterheatercoldwaterinletconnection.Thisproceduremay
needtoberepeatedtoensurethestrainerremainsclean,especiallyatasiteofanewdwelling.
Ifremotecontrolisfitted,itisnecessarytotesttheallfunctions&operationsoftheremotecontrol.
Confirm the hot water heater delivery temperature by using a thermometer. If remote control is fitted,
ensuretemperatureexceeding50°Ccannotbeselectedatbathroomoren‐suiteremotecontrol.
Afteralltestsarecompleted,theinhabitantsof the dwellingshouldbemadeawareof the functions and
operationsofthehotwaterheaterandremotecontrol(iffitted).
EnsuretheProductRecordonpage44isfilledinandthisbookletishandedtotheinhabitants.