WaterSupply
RefertoTable1,Page6,forwatersupplypressurerequirements. An approved pressure limiting valve may be
requiredifthemaximumwaterpressureexceedsthefigureshowninTable1.Inordertoobtainedoptimalhotwater
flow, minimum water supplypressurestatedinTable 1 mustbemet.Thehotwaterheatermayoperateatlower
pressure,howeverratedflowmaynotbeachieved.ContactONSENforgravityfedorlowpressureinstallations.
WatersupplyinmostcitieswillmeetthewaterqualityrequirementsasshowninTable2.Ifyouareunsureabout
yourlocalwaterquality,contactthewaterauthority.Ifsludgeorforeignobjectsarepresentinthewatersupply,a
suitablefilterorstrainershouldbeincorporatedinthewatersupplytowaterheater.
The water heater MUST ONLY be used in the following water supply conditions to prevent product damage and
operationfailure.
Clean,potablewaterfreefromcorrosivechemicals,sand,grit,andothercontaminants.
Inletwatertemperatureabove1°C,butnotexceeding48°C.
DoNOTreverseHOTandCOLDwaterconnections.
DoNOTconnectthiswaterheatertowaterlinespreviouslyused for space heating. All water piping and
componentsshallbesuitableforpotablewaterlines.
WithrecommendedwaterqualityasshowninTable2.
pH TDS
(Total
Dissolved
Solids)
Free
Carbon
Dioxide
(CO2)
Tota l
Hardness
Aluminium Chlorides Copper Iron Manganese Zinc
6.5 ‐
8.5
Up to
500mg/L
Up to
15mg/L
Up to
200mg/L
Up to
0.2mg/L
Up to
200mg/L
Up to
1.0mg/L
Up to
0.3mg/L
Up to
0.05mg/L
Up to
1.0mg/L
Table2