InstallationInstructions
This appliance shall be installed by authorised personnel in accordance to the manufacturers instructions and
currentlocalelectrical,gas,andwaterregulations.
Thisappliancemustbeinstalledinaccordancewith:
AS/NZS3000–ElectricalInstallations(WiringRules)
AS/NZS3500.4–PlumbingandDrainage(HeaterWaterServices)
AS/NZS5601–GasInstallations(forAustralia)
Localbuilding,water,andgasfittingregulations
LocalregulationsandmunicipalbuildingcodesincludinglocalOH&Srequirements
InstallationEnvironment
ThishotwaterheaterisdesignedforOUTDOOR
installationonly.
Thehotwaterheatermustbeinstalledinapositionwhereitisaboveground,inopenairwithnaturalventilation,
where,inthecaseofgasleakageorproductcombustion,gascanbereleasedanddispersedrapidlybyventilationor
convection.
Theunitmustbemountedverticallywiththewaterandgasconnectionsontheundersidepointingdownwards.
Forappliancesinstalledonelevatedstructuresorunderfloorsspecificrequirementsmustbeadheredto.
RefertoAS/NZS5601Section6formoreinformation.
The appliance flue terminal must be located in accordance to Section 6 and Figure 6.2 of AS/NZS 5601. The
requirementsarereproducedandshownonpage7,Figure4.
Note:ReferencestoAS/NZS5601arecurrentatthetimeofprintingbutitistheinstallersresponsibilitytoensure
anysubsequentchangesinregulationsareadheredwithinfull.
Theappliancemustbeinstalledclosetothemostfrequentlyusedhotwateroutlettominimisedelaytimeforhot
water delivery. Alternatively, it is possible to strategically install multiple units to provide hot water for several
outletswithminimaldelaytime.ContacttheauthorisedCustomerServiceCentreforfurtherinformation.
Theunitmustbeinstalledadjacenttoa240Vac,10Amp,earthed,powerpoint.Foroutdoorinstallations,thepower
pointmustbeweatherproof.Thispowerpointmustnotbeinthewayofflueexhaust,waterpressurereliefvalve,or
gas&waterconnectionstotheappliance.
Thelengthoftheappliancepowercordis1.5m.
Theinstalledhotwaterheatermustbeeasilyaccessibleforinspection,servicing,oroperationalpurposes.Sufficient
clearancesareneededtoallowaccessto,orremovalof,allserviceablecomponents.
The unit should not be mounted higher than 2.5m above ground orfloorlevelunlessthecustomercanarrange
permanentandsafeaccesstotheunit.
The water heater should not be installed near an air supply containing halogenated hydrocarbons where
contaminants can be intermixed with non‐polluted air supplying thecombustionprocess.Theaircontaining