Electrical Installation
WIRING INSTRUCTIONS
1. Check product label for correct
voltage and wattage. Make sure
power source conforms to the
heaters requirements.
2. The junction box on the top of
the heater has a gasket side
access cover. The junction box
inlet is drilled and threaded for a
standard 1/2" (19 mm) weather
tight conduit  ttings. The installing
electrician will need to provide the
appropriate rigid metallic,  exible
or liquid tight conduit, conduit
ttings for installation location.
3. For outdoor installation all
connections must be made
in accordance with local
electrical code regulations for
outdoor wiring. Only use wiring
components approved for outdoor
use with minimum NEMA Type 4x
or equivalent.
4. Remove the screws holding the
junction box cover. Make the
electrical connections using wire
nuts (not supplied). The green
wire connects to the ground. The
black wire connects to the black
wire (neutral) from your house.
The white wire connects to the
white wire (live) from your house;
5. Assemble the junction box cover
& gasket. Ensure that the junction
box cover gasket (supplied with
unit) is installed to maintain
rain water ingress protection
rating of the heater. failure to
install correctly will void the
manufacturer’s warranty.