Grill Specications
Burner 4 Burner
Injector Size 1.0 MM
Gas/Pressure 11" per W.C
Input Rate 11,700 BTU/HR*3 (main) 14,000 BTU/HR*1 (searing)
Standard ANSI STD Z21.58-2018 Outdoor Cooking Gas Appliances
TECHNICAL AND SERVICING INFORMATION
This appliance is designed for outdoor use only using Propane gas at a supply pressure of 11" per WC
and must be serviced by a competent person in accordance with the instructions included. Please read all
accompanying documentation carefully.
TROUBLESHOOTING
Problem Possible Cause Solution
Burner will not light using LP gas cylinder is empty Replace with full cylinder
the ignition system
Faulty regulator Have regulator checked
or replace
Obstructions in burner Clean burner
Obstructions in gas jets or gas hose Clean jets and gas hose
Electrode wire is loose Reconnect wire
Electrode or wire is damaged Change electrode and wire
Low ame or ashback Obstructions in burner Clean burner
(re in burner tube - a
hissing or roaring noise may
be heard
Obstructions in gas jets or Clean jets and gas hose
gas hose
Windy conditions Use grill in a more
sheltered position
Gas valve knob dicult to Gas valve jammed Replace gas valve
turn