11
WARNING Risk of electrocution. Use of an extension
cord could cause electric shock or burn resulting in
death or serious injury.
DO NOT use an extension cord with this electric
pressure washer. Your home’s electrical circuit receptacle or
extension cord may not provide lifesaving ground-fault
circuitinterruption protection.
7. Plug electrical power cord into an electrical circuit rated
for 120 Volts AC at 15 Amps that is properly installed
in accordance with all local codes and ordinances. The
indicator light on the GFCI should be ON.
NOTICE The power supply must be 120 V, 60 Hz and a minimum
15 amp dedicated circuit.
NOTICE The indicator light must be ON for the electric pressure
washer to operate.
WARNING Risk of electrocution. Non-operating ground
fault circuit interrupter (GFCI) could result in death
or bodily injury. If indicator light does not stay ON
after test and reset, do not use GFCI.
8. Press TEST button (B). The indicator light (D) should be OFF.
B
D
C
9. Press RESET button (C). The indicator light (D) should be ON.
NOTICE DO NOT use the electric pressure washer if above test
fails.
10.
11.
Press the master ON/OFF switch (A) to the Pressure Washer
ON ( | ) position.
Point gun in a safe direction, open trigger lock small lever
and squeeze trigger. The electric pressure washer motor
will start as the spray gun trigger is depressed and will
continue to run even when released.
The electric pressure washer is now ready for use. Instructions
for use of the supplied accessories are given later in this section.
Operation
Start Pressure Washer
Follow the instructions below in the order presented.
WARNING Risk of eye injury.
Spray could splash back or propel objects resulting
in serious injury.
Always wear indirect vented (chemical splash)
safety goggles marked to comply with ANSI Z87.1 when
using or in vicinity of this equipment. NEVER substitute
safety glasses or dry-condition goggles for indirect vented
safety goggles.
1. Place the electric pressure washer near an outside water
source capable of supplying water at a flow rate greater than
5 GPM (18.9 LPM) and no less than 20 PSI (1.38 BARS) at the
electric pressure washer end of garden hose. DO NOT siphon
supply water.
2. Connect garden hose to water inlet.
3. Check that high pressure hose is tightly connected to spray
gun and high pressure outlet. See Connect Hoses and Water
Supply.
NOTICE DO NOT run the pump without the water supply
connected and turned on.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
4. Turn ON water, point gun in a safe direction, open trigger lock
small lever and squeeze trigger to purge pump system of air.
5. Install desired spray tip into wand. See Connect Wand and
Spray Tips.
6. Press master ON/OFF switch (C) to OFF (0) position
C
WARNING
Do not allow the unit to run for more than two
minutes without the gun trigger being pulled.
This could cause overheating and damage to the
pump. When the temperature inside the pump rises
too high, the thermal relief valve will open and
release a spray of water from the pump to lower
the internal temperature. The valve will thenclose.
ON
OFF
Loading ...
Loading ...