Design Guide - Standard Installation
THE INSTALLATION SPACE
Water And Electrical Locations
The opening must be prepared with the electrical and
the cold water supply located as shown.
The Cutout Depth Must Be 24”
The refrigerator will project forward, slightly beyond
adjacent cabinetry for standard installation.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on the rear wall as shown.
NOTE: GFI (ground fault interrupter) is not
recommended.
• The water line can enter the opening through the
floor or back wall. The water line should be 1/4”
O.D. copper tubing or SmartConnect
kit between
the cold water line and water connection location,
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in
the water line is required.
DIMENSIONS AND CLEARANCES
* Shipping height.
The refrigerator can
be adjusted to fit
into a cutout that is
84-1/2” in height.
Use leveling legs
and wheels for a
maximum 1” height
adjustment.
Product Clearances
These refrigerators are
equipped with a 3-position
door stop. The factory-
set 115° door swing can
be adjusted to 130°, or
to 90° on panel models
or 90° on stainless steel
models if clearance to
adjacent cabinets or walls
is restricted.
6
90° Door Swing
130° Door Swing
(Panel Models Only)
115° Door Swing
*Finished Width
6"
5"
Electrical
Area
85" max
Finished
Opening
75" From Floor
to Bottom
of Electrical
Area
24"
5"
5"
3 1/2"
Water Supply
3 1/2"
36" Models 12"
42" Models 18"
48" Models 20"
Panel Models Only: Allow minimum clearances for
the freezer door (Dimension A) and fresh food door
(Dimension B) for a full 130° door swing and to allow
for pan removal.
For a 90° door swing, allow 4” min. clearance to a
wall. If the 90° door stop position is used, pan access
is maintained, but pan removal is restricted.
See the illustrations on pages 10 and 11 to determine
door swing interaction with adjacent cabinets or
countertops.
Models A B C
36” 13” 15” 20-5/8”
42” 13” 19” 26-5/8”
48” 15” 20” 28-5/8”
*84"
From
Floor
25-3/8" Framed Models
Depth Including Handles 26-7/8”
36", 42" or 48"
Frame to Frame
35", 41", or 47"
Case Width
*83-1/2"
at
Rear
23-7/8"
Behind
Frame
C
*Min. Distance
to Wall
4”
B
A
*The finished cutout width must be:
35-1/2” for 36” models
41-1/2” for 42” models
47-1/2” for 48” models