TEC_TM_156 | REV. D | EN 9/12/2022 Page 89 of 9615 & 24 INCH INSTALL GUIDE
SERVICING & ADJUSTMENTS
Q. How do I adjust the temperature?
A. Refer to True Precision Control
®
Operation listed
in Table of Contents on page 64.
Q. Why does the evaporator fan motor run constantly?
A. This is a normal operation in wine units. The
evaporator fan motor will run continuously to ensure
even temperature throughout your cabinet. This will
only stop when the door is opened to keep warm air
from being circulated throughout the cabinet.
Q. Why isn’t my unit cooling properly?
A. Check to see that there are no obstructions to the
condenser coil (behind front grill). Confirm that the
condenser area is clean.
Q. How do I adjust or remove a shelf from my current
configuration?
A. Refer to Glass Shelf Adjustment listed in Table of
Contents on page 52.
Q. Why is there warm air coming from the bottom/
front of the refrigerator (grill/kickplate area)?
A. This is normal as heat dissipation is part of the
refrigeration cycle.
Q. Why is there condensation forming on the inside
or outside of the unit?
A. Leaving the door open for a long period of time or a
unit that is running with little to no product inside may
also cause excessive condensation.
Q. What are the preset limits for the high
temperature alarm?
A. The electronic control will monitor temperatures and
activate an alert if unsafe product temperatures are
present for more than 60 minutes. For single and dual
zone wine cabinets, the alarm will activate at 70°F. For
all refrigerators, the alarm will activate at 50°F.
Q. How much distance is needed from the wall to
have the hinge on the wall side and still open 90
degrees?
A. 2 inches.
Q. Can I put 2 units flush against each other
without spacing?
A. When installing two or more True units side-by-side,
be sure to leave at least 5/8" (16 mm) gap between the
cabinets, or install foam pads between the cabinets
and on any side with 0” clearance, to prevent moisture
from developing on applications. If installing anti-sweat
foam end panels, True recommends applying a panel
to one of the units being joined together. To order foam
pads, contact our parts department at
844-849-6226 or TrueResidentialParts@TrueMfg.com.
Q. Does True sell the wood doors on overlay?
A. No, for wood front doors, reach out to your cabinet
maker and provide them with the overlay template
available on the right hand side of our document
library: http://www.true-residential.com/Support/
Document-Library/
Q. Does the overlay come with the handle?
A. No, our handle can be ordered as an accessory,
or any pull can be added to your overlay drawer.