TROUBLE SHOOTING
FAULT POSSIBLE CAUSE SOLUTION
Light on, but motor does
not work
• Fan switch turned off • Select a fan switch position
• Fan switch failed • Contact service center
• Motor failed • Contact service center
Light on, but motor does
not work
• House fuses blown • Reset/Replace fuses
• Mains power cable is loose or disconnected • Ret mains power cable to power outlet
• Switch power outlet on
Oil leakage • One way valve and the outlet are not tightly
sealed
• Take down the one way valve and seal with
sealant
• Leakage from the connection of chimney and
cover
• Take chimney down and seal
Lights not working • Broken or faulty bulbs • Replace bulbs as per this instruction
Insufcient suction • The distance between the range hood and the
gas top is too far
• Ret the range hood to the correct distance
The Range hood inclines • The xing screw is not tight enough • Tighten the hanging screw and make it
horizontal