Installation
www.bora.com
HR uključeno: Prirodni plin H I2H 20 mbar
IE set for: Natural gas H I2H 20 mbar
IS sett á: jarðgas H 20 mbar
IT aggiustato a: Gas naturale H I2H 20 mbar
LT nustatytas: Gamtinės dujos H I2H 20 mbar
LU festgeluecht: Natierlech Gas E 20 mbar
LV ieslēgts: Dabasgāze H I2H 20 mbar
MT issettjat fuq: Gass naturali H 20 mbar
NO satt på: Naturgass H I2H 20 mbar
PL ustawić: Gaz ziemny E I2H 20 mbar
PT regulado para: Gás natural H I2H 20 mbar
RO setat pe: Gaz natural H I2H, I2E 20 mbar
SE sätt på: Naturgas H I2H 20 mbar
SI nastavljen na: Zemeljski plin H I2H 20 mbar
SK zapnuté: Zemný plyn H I2H 20 mbar
TR ayarlamak: Doğal gaz H I2H 20 mbar
Tab. 5.5 Gas cooktop default settings
The stamp on the nozzles corresponds to the values in the
nozzle table and can be found either on the top or side of the
nozzles.
Gas type/gas
pressurembar
Ø SR burner/
normal burner
Ø R burner/
high-power
burner
G20/20 104 125
G25/20 110 131
G20/13 115 149
G25/25 G25.3/25 104 131
G20/25 100 119
G30/37
G31/37
69 85
G30/50 G30–50mbar 62 78
Tab. 5.6 Nozzle table
Total nominal connection values for liquid gas:
Gas type mbar kW g/h m³/h
G30/G31 50 4.90 364 0.143
G30 29 5.00 364 0.143
Tab. 5.7 Liquid gas nominal connection values
Total nominal connection values for natural gas:
Gas type mbar kW m³/h
G20 20 5.00 0.48
G25 25 5.10 0.55
G25.3 25 5.10 0.54
G20 13 5.00 0.48
G25 20 4.80 0.55
Tab. 5.8 Natural gas nominal connection values
Special nozzle table for Australia and NewZealand:
AUS / NZS
gas type Ø SR burner/
normal burner
Ø R
burner
NG/1.0 kPa (G20/10) 1.22 1.55
ULPG/2.75 kPa (G31/27,5) 0.75 0.92
Tab. 5.9 Nozzle table (Australia and New Zealand)Total nominal
connection values for U-LPG/
2.75 kPa test point pressure: 18.6 Mj/h
Cooktop energy consumption AU/NZ – U-LPG/
2.75 kPa test point pressure:
High Power front burner 11.2 Mj/h
Normal back burner  7.4 Mj/h
Total nominal connection values for NG/
1.0kPa test point pressure: 19.5 Mj/h
Cooktop energy consumption AU/NZ – NG/
1.00 kPa test point pressure:
High power front burner 12.0 Mj/h
Normal back burner  7.5 Mj/h
1
2
3
4
5
6
Abb. 5.23 Gas burner structure
[1] Burner cap
[2] Burner head
[3] Electric igniter
[4] Safety thermocouple
[5] Burner housing
[6] Gas burner nozzle
X
Remove the pan support.
X
Remove the burner cap [1] from the burner head [2].
X
Remove the burner head [2] from the gas outlet.