LG LMQN150HV Air Conditioner Cooling Area, Adjustable Air Direction

User Manual - Page 79

For LMQN150HV.

PDF File Manual, 243 pages, Read Online | Download pdf file

LMQN150HV photo
Loading ...
Loading ...
Loading ...
STD. WALL-MOUNTED | 79
Low Wall Console
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F
Acoustic Data
LOW WALL CONSOLE INDOOR UNITS
Measurement taken 2.6′ below the bottom of the unit and at a
distance of 3.3′ from face of unit.
Measurements taken with no attenuation and units operating at full
load normal operating condition.
Sound level will vary depending on a range of factors such as
construction (acoustic absorption coefficient) of particular area in
which the equipment is installed.
Sound power levels are measured in dB(A).
Tested in anechoic chamber per ISO Low 3745.
Model No.
Sound Pressure Levels (dB[A]) (Cooling and Heating)
High Fan Speed
Medium Fan
Speed
Low Fan Speed
LQN090HV4 38 32 27
LQN120HV4 39 32 27
LMQN150HV 44 39 35
Figure 97: Sound Pressure Level Measurement Location.
Table 38: Sound Pressure Levels (dB[A]).
2.6 ft.
3.3 ft.
Microphone
Figure 98:LQN090HV4 and LQN120HV4 Sound Pressure Level Diagrams.
LQN090HV4 LQN120HV4
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
63 125 250 500 1000 2000 4000 8000
Octave Band Sound Pressure Level (0dB = 20μPa )
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
63 125 250 500 1000 2000 4000 8000
Octave Band Sound Pressure Level (0dB = 20μPa )
Octave Band Center Frequency (Hz)
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Loading ...