Single Zone High Efciency, Standard, Extended Pipe and Mega Wall Mount Installation Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
GENERAL DATA
Type Single Zone Extended Pipe Units
System Model Number (IDU/ODU)
LS240HLV (LSN240HLV/
LSU240HLV)
LS300HLV (LSN300HLV/
LSU300HLV)
LS360HLV (LSN360HLV/
LSU360HLV)
Piping
Liquid Line (in, OD)
3/8 3/8 3/8
Vapor Line (in, OD)
5/8 5/8 5/8
Condensation Line (OD, ID)
27/32, 5/8 27/32, 5/8 27/32, 5/8
Additional Refrigerant Charge (oz/ft)
0.38 0.38 0.38
Max Pipe Length
5
(ft)
164 164 164
Piping Length
5
(no add’l
refrigerant, ft)
24.6 24.6 24.6
Max Elevation Difference (ft)
98.4 98.4 98.4
Table 3: Single Zone Extended Pipe Unit Specications - Continued
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit
5
Piping lengths are equivalent.
Power wiring is field supplied and must comply with the applicable local and national codes
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level
difference outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).