Craftsman 13953915DM garage door opener

User Manual - Page 20

For 13953915DM.

PDF File Manual, 76 pages, Download pdf file

Loading ...
Loading ...
Loading ...
INSTALLATION STEP 10
Install The Protector System®
Thesafety reversingsensormust be connectedandaligned
correctlybeforethe garage door openerwill move in the down
direction.
IMPORTANTINFORMATIONABOUTTHESAFETYREVERSINGSENSOR
When properly connected andaligned, the sensor will detect an
obstacle in the path of its electronic beam. The sending eye (with
an amber indicator light) transmits an invisible light beamto
the receiving eye (with a green indicator light). If an obstruction
breaksthe light beam while the door is closing, the door will stop
and reverseto full open position, and the opener lights will flash
10 times.
The units must be installed inside the garageso that the sending
and receivingeyesface each other across the door, no more than
6" (15 cm) abovethe floor. Either can be installed on the left or
right of the door as long as the sun never shines directly into the
receiving eye lens.
The mounting brackets are designedto clip onto the track of
sectional garage doors without additional hardware.
Besure power is NOTconnected to the garagedoor opener
BEFOREinstalling the safety reversing sensor.
To preventSERIOUSINJURYor DEATHfrom a closing garage
door:
Correctly connect andalign the safety reversing sensor. This
required safety device MUST NOTbe disabled.
Install the safety reversing sensor so beam is NO HIGHER
than 6" (15 cm) abovegaragefloor.
If it is necessaryto mount the units on the wall, the brackets must
be securely fastened to a solid surface such as the wall framing.
Extension brackets (seeAccessories) are availableif needed.If
installing in masonry construction, add a piece of wood at each
location to avoid drilling extra holes in masonry if repositioning is
necessary.
The invisible light beam path must be unobstructed. No part of
the garagedoor (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door is closing.
!o! !÷[ !€
Safety Reversi n;211111 7 2"'7ir_i_i ii [f.7;t_;tYZ 2".7"_:: 'g sor
6" (15 cm) max. abovefloor Protection Area 6" (15 cm) max. above floor
Facingthe doorfrom insidethe garage
2O