40
5 Maintenance
TRemove and empty the water tank.
TCompletely dissolve 3JURA descaling tablets in a receptacle
holding 600ml of water. This may take several minutes.
TPour the solution into the empty water tank and insert it
into the machine.
‘Press the Rotary Switch’
TPlace a receptacle under the hot-water spout.
TPress the Rotary Switch.
‘Machine is being descaled’, water flows out of the hot-water
spout repeatedly.
The operation is interrupted,
‘Empty drip tray’.
TEmpty the drip tray and coffee grounds container and put
them back into the machine.
‘Fill water tank’
TEmpty the receptacle and place it under the hot-water and
dual spouts.
TRemove the water tank and rinse it thoroughly.
TFill the water tank with fresh, cold water and reinsert the
tank.
‘Press the Rotary Switch’
TPress the Rotary Switch.
‘Machine is being descaled’, the descaling operation is con-
tinued, water flows out of the dual spout and the hot-water
spout.
‘Empty drip tray’
TEmpty the drip tray and coffee grounds container and put
them back into the machine.
The start screen is displayed. Your Z6 is once more ready for
use.
E If the descaling operation stops unexpectedly, rinse the water
tank thoroughly.