Loading ...
Loading ...
Loading ...
INSTALLATION
76 77
Procedure
• Remove the grill and the burners from the hob.
• Unscrew injectors “U” using a 7-mm spanner (g. 8, g 10) and replace them with
those for the new gas according to table number 3.
ADJUSTMENT
- Replacement of the injectors for models “K” “V” Series
1
2
U
U
When installing the cooker you must check that the minimum gas ow of the burners
on the hob and in the oven is correctly regulated.
If the type of gas is changed the minimum ow must also be adjusted.
The regulating procedure is as follows.
Burners on the hob:
1. Light one burner at a time and turn the ame up to maximum.
2. Remove the knob of the corresponding gas tap and insert a screwdriver in the
end part of the tap or in the screw (g. below).
3. Turn the tap to minimum position.
4. Unscrew, turning to the left, to increase the ame, or screw
to the right to decrease it.
5. Refer to the table below for adjustment settings.
Procedure:
SR - R - P
Procedure:
DCC (DUAL WOK)
• Remove the grill and the burners from the hob.• SR – R – P :
SR – R – P burners: unscrew injectors “U” using a 7-mm spanner (g. 1) and replace
them with those for the new gas according to table number 2 on page 20.
• DCC – Dual burners: unscrew the 2 screws “P” and remove cover “C” g.2.
• unscrew injectors “U” using a 7 mmspanner (g.3, g.4) and replace them with those
for the new gas according to table number 1 below 13.
ADJUSTMENT
- Replacement of the injectors for models
2
1
3
4
U
U
U
Loading ...
Loading ...
Loading ...