8.3.2 Menu item S: GASt
INFO Under menu item S (GASt) you can select the
characteristic curves for the gas burners.
The characteristic curves regulate the minimum gas
burner power values. The minimum power levels are
adjusted using the characteristic curves. Depending on
the installation situation and the influence of the cooktop
extractor, if necessary, the characteristic curve can be
changed:
A enables the fine tuning of the power values, which can
only be adjusted in the best-case scenario. The best-case
scenario is when:
no cooktop extractor is in operation; or
the cooktop, when using the cooktop extractor in
exhaust air mode, is used with sufficient ventilation; or
the cooktop, when using the cooktop extractor in
recirculation mode is used with a sufficient return flow
aperture and the cooktop extractor does not have a
negative influence on the gas flame.
B is the factory default characteristic curve with balanced
adjustment of the individual power levels.
C increases the lower power levels and should only
be used in the event of a negative influence from the
cooktop extractor.
Fig. 8.6 Display menu item S: GASt
Select the appropriate characteristic curve (tap the
corresponding slider segment ).
8.3.3 Menu item T: GAS
INFO Menu item T (GAS) provides a reset function. This
reset function can be used in the case of faults
and errors and during initial operation if the gas
cooktop does not react (does not ignite).
INFO The gas type and gas pressure values set remain
unchanged and are not affected by the reset.
Fig. 8.7 Display menu item T: GAS
Reset the system if necessary
(tap the sl
ider zone
).