SECTION 1. Introduction
Features:
This manual is organized into four sections:
Designing The Installation • Installation
Inspection and Testing •Operation
The heating mat’s edge is left unsealed from the factory so that
it can be cut to fit and then sealed for proper moisture proofing.
If cutting is not needed, sealing the edge of the mat is still
required. Familiarize yourself with sealing the mat’s edge on
page 10, step 3.
Peel & Stick Radiant Heat Film should be installed on properly
prepared stable subfloors. Do not use glue, nails, or other
mechanical fasteners
Peel & Stick Radiant Heat Film must be installed on a dedicated 20
amp circuit. Do not connect lights, outlets, or any other electrical
device to any branch circuit used with the underlayment.
All wiring, fuses and/or circuit breakers must conform to National
Electrical Code requirements.
Maximum thermal resistance permitted above Peel & Stick
Radiant Heat Film is R-1.5.
Materials which may not contact Peel & Stick Radiant Heat Film
include any sheet vinyl or linoleum floor coverings.
All wiring must run through conduits to junction boxes.
How to Use This Manual
Before You Begin
The Peel & Stick Radiant Heat Film mats are a unique floor heating system with anti-fracture membrane installed
under thin-set installations of tile, stone, and marble. Completely unseen, Peel & Stick Radiant Heat Film combines
easy release liner installation with anti-fracture protection to provide warmth and comfort to tile, stone, and marble.
Peel & Stick Radiant Heat Film is a safe and efficient electric floor warming product for interior applications. It
cannot be used for exterior snow melting applications. It is intended for installation below tile, stone, marble, and
other masonry flooring materials in residential and moderate commercial installations.
Peel & Stick Radiant Heat Film can be used to heat a room as well as to warm the floors. Refer to “Heat Loss
Calculations” on page 4 for further information. Peel & Stick Radiant Heat Film is designed to deliver 12 watts per
square foot. The floor temperature attainable is dependent upon how well the floor is insulated, the temperature
of the floor before start up, and in the case of uninsulated slab applications, the thermal transfer of the underlying
materials. Peel & Stick Radiant Heat Film ’s efficiency is maximized with a well insulated sub floor.
0.03” thick and easy to install
3/8 inch crack isolation
Draws 12 watts per sq. ft.
Produces 41 BTUs per sq. ft.,
providing even heat throughout
Available in 18” and 36” widths in
standard kit lengths or custom lengths
2-in-1 Kits are available in 18” and 36”
widths and feature factory attached
leads on both ends of mat. Designed
to be cut apart to desired lengths for
less waste and versatile coverage.
120V or 240V
Thermostat controlled
Warranted to be free of defects
in manufacture for a
period of 25 years
Installation & Owners Guide 1
2
1
Loading ...
Loading ...
Loading ...