Drolet-DG049058
Room heater
DV30
Gas type
Gas A
(LNG)
Gas E
(LPG)
Max heating value
Btu 9300 9300
Min heating value
Btu 4740 4740
Minimum gas pressure before valve
W.C. 3.5 8.0
Maximum gas pressure before valve
W.C. 8.48 21.2
Gas pressure after valve for max
W.C. 4.0 10.0
Injector main burner /
n.
Ø inch
Ø mm
1
0.059
1.50
1
0.037
0.95
Injector pilote burner
n.
Ø inch
Ø mm
1
0.017
0.42
1
0.007
0.19
Voltage rating / mains frequency
120 V AC / 60Hz
Electrical consumption
W/H 37
Annual fuel utilization efciency
% 73,66
Reference standards "ANSI Z21 86-2016 • CSA 2.32-2016"
Predispose for
GAS E
Intake pressure
W.C. 11
Manifold pressure
W.C. 10
Room heater
DV45
Gas type
Gas A
(LNG)
Gas E
(LPG)
Max heating value
Btu 13750 13750
Min heating value
Btu 7536 7536
Minimum gas pressure before valve
W.C. 3.5 8.0
Maximum gas pressure before valve
W.C. 8.48 21.2
Gas pressure after valve for max
W.C. 4.0 10.0
Injector main burner
n.
Ø inch
Ø mm
1
0.071
1.80
1
0.046
1.16
Injector pilote burner
n.
Ø inch
Ø mm
1
0.017
0.42
1
0.007
0.19
Voltage rating / mains frequency
120 V AC / 60Hz
Electrical consumption
W/H 55
Annual fuel utilization efciency t
% 76,85
Reference standards "ANSI Z21 86-2016 • CSA 2.32-2016"
Predispose for
GAS E
Intake pressure
W.C. 11
Manifold pressure
W.C. 10
NOTE: Minimum Gas Inlet Pressure for purpose of input adjustment.The efciency rating of the appliance is
a product thermal efciency rating determined under continuous operating conditions and was determined
independently of any installed system.