Drolet-DG04905 7
PRODUCT IDENTIFICATION
SPECIFICATIONS, DIMENSIONS AND ADVERTISING
These units are independent gas appliances for space heating. They use an atmospheric burner with an airtight
combustion chamber. This guarantees maximum safety because it does not allow exhaust fumes or gas leak
in the habited environment. The intake of the combustion air and the exhaust of the combustion fumes takes
place outside the environment through two concentric tubes, thanks to the balanced draft created by the
ascending force of the fumes. They can be installed in narrow spaces and are equipped with a humidifying
tray. They are assembled, in the factory, for operation with Gas "E" (LPG), but can be converted for Gas "A"
(LNG) operation, using the nozzle kit supplied.
The thermostatic ignition/control/regulation valve, controls all main functions and automatically shuts off the
gas supply in case of malfunction.
The control panel allows you to switch on the appliance’s electrical power (appliances with tangential fan or
timer only), to start and stop it manually or automatically using the thermodisc, to set its heating power and
start/stop the fan, adjust the room temperature setting and restore operation after a malfunction.
In Canada, the CSA C22.1 Canadian National Electrical Code and in the U.S.A, the NFPA 70 National Electrical
Code are to be followed in the absence of local code requirement.
cabinet
Back
Control panel
door
grill
Guard
Burner
inspection
holes
Blower
coverage
Front
cabinet
A
C
B
Model Input
Nom./Red.
kW
A
Width
B
Depth
C
Height
Gas
Connection
Type
gas
MAX wall
thickness
MIN wall
thickness
DV30 3,49/1,42 25,27 8,85 33,77 1/2” Gas "E"(LPG) 35,43 5
DV45 5,11/2,04 32,36 8,85 33,77 1/2” Gas "E"(LPG) 35,43 5
LNG: Liquefied Natural Gas
LPG: Liquefied Propane Gas