Drolet-DG04905 21
ADJUSTMENTS
WARNING: Adjustments must be done by a qualied service technician, using only the orignal parts attached
to the appliance.
WARNING: First of all, you must change the conguration into the gas regualtor according the kind of gas that
you want to use. Follow the steps below carefully.
Figure 1: unscrew the hexagonal seal cap.
Figure 2: there is a plastic plug clipped in the seal cap. The plug has small end marked with Gas "A"(LNG) and
a bigger end marked with Gas "E"(LPG).
Figure 3: the plug must be clipped in the right position to achieve the requested outlet pressure:
- small side facing the regulator and bigger side facing the seal cap => outlet pressure for Gas "A"(LNG)
- bigger side facing the regulator and small side facing the seal cap => outlet pressure for Gas "E"(LPG)
Figure 4: screw in the sealcap.
7. Change the gas label and seal the adjustment equipment once it is calibrated, with a drop of paint
or silicone. Never leave the old gas label on the appliance; this can lead to misunderstanding and
is hence very hazardous.
IMPORTANT: To complete the conversion from a kind of gas to other you must change the conguration on the
gas regulator and follow carefully the instructions in the Chapter ADJUSTMENTS only for “minimum pressure”
according the kind of gas.