Drolet-DG04905 21
ADJUSTMENTS
WARNING: Adjustments must be done by a qualied service technician, using only the orignal parts attached
to the appliance.
WARNING: First of all, you must change the conguration into the gas regualtor according the kind of gas that
you want to use. Follow the steps below carefully.
Figure 1: unscrew the hexagonal seal cap.
Figure 2: there is a plastic plug clipped in the seal cap. The plug has small end marked with Gas "A"(LNG) and
a bigger end marked with Gas "E"(LPG).
Figure 3: the plug must be clipped in the right position to achieve the requested outlet pressure:
- small side facing the regulator and bigger side facing the seal cap => outlet pressure for Gas "A"(LNG)
- bigger side facing the regulator and small side facing the seal cap => outlet pressure for Gas "E"(LPG)
Figure 4: screw in the sealcap.
7. Change the gas label and seal the adjustment equipment once it is calibrated, with a drop of paint
or silicone. Never leave the old gas label on the appliance; this can lead to misunderstanding and
is hence very hazardous.
IMPORTANT: To complete the conversion from a kind of gas to other you must change the conguration on the
gas regulator and follow carefully the instructions in the Chapter ADJUSTMENTS only for “minimum pressure”
according the kind of gas.