Loading ...
Loading ...
Loading ...
Drolet-DG0490520
GAS CONVERSION INSTRUCTION
The room heater is suitable, and it is possible to
change, in every moment ,the conguration from a
type of gas to another type, i.e. from Gas "E" (LPG) to
Gas "A"(LNG).
To make this conversion follow the below instructions,
step by step:
- Disconnect the electrical power supply.
- Remove the jacket.
- Shut off the gas supply and disconnect the pipes.
PILOT BURNER INJECTOR REPLACEMENT
1. Unscrew the M10x1 collar (1) from the pilot
burner fitting, extract the gas pipe(2) with the
injector (6) still attached to it.
2. Replace the injector(6) with the one for the
new gas type.
IMPORTANT: Make sure that the groove on the head
of the injector (6) ts onto the key on the gas outlet (3).
3. In reverse order, replace the pipe with the
injector connected to it, taking care not to
dislodge or crush it at the beginning , clamping
the collar manually, at the end, complete this
operation with a wrench. The seal of the
injector is mechanic, so there is no need for
a gasket.
3
1
2
6
(LPG)
Model
DV30
main burner
pilot
(LNG)
1,65 1,05
mm
Ø
0,42 0,19
Ø
DV45
main burner
pilot
1,98 1,25
Ø
0,42 0,19
Ø
WARNING: Conversion must be done by a qualied service technician, using only the orignal parts attached
to the appliance.
MAIN GAS BURNER INJECTOR REPLACEMENT
1. Unscrew the collar (4, 3/8” F) from the MAIN
BURNER Injector mount fitting;
2. Unscrew the injector mount fitting from the
injector itself;
3. Unscrew the injector (5) and replace it with the
new one. Thread it on by hand and only then tighten it
down with a wrench. The seal of the injector and of the
injector mount tting is mechanic, so there is no need for
a gasket.
4. Check that the value stamped on the injectors match those in the table.
5. Restore the burner unit in reverse order.
6. Make the adjustments indicated in Chapter ADJUSTMENTS; also check that the gas fittings on
thepipe running from the gas cock to the burner unit are tight.