User Manual - Page 31

For B36NTR-1.

PDF File Manual, 152 pages, Read Online | Download pdf file

B36NTR-1 photo
Loading ...
Loading ...
Loading ...
EN
W415-2835 / B / 04.05.21
31
rough framing
MAXIMUM REAR VENT CLEARANCES
(EXAMPLE 1: INTERIOR NICHE / BUMPOUT / ALCOVE)
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
6 3/8"
[162mm]
41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
* See "venting" section.
The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.