venting requirements
Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when
nal grading is completed, the bottom air slot is located a minimum 12” (305mm) above grade. The maximum
allowable vent length (including both rise and run) is 10’ (3m) for a fi replace and 8’ (2m) for a stove. An insulation
sleeve is illustrated in the top vent image below, use only when supplied with the appliance.
(The insulation sleeve is not required with a stove appliance)
TOP VENTREAR VENT
2.2 special vent installations
2.2.1 periscope termination
12" (30.5cm)
minimum
to grade
30" (76.2cm)
minimum
30" (76.2cm)
minimum
34 5/8"
(87.9cm)
20” (50.8cm)
MAXIMUM
6” (152mm)
RISE MINIMUM
2.2.2 corner termination
The maximum vent length for a corner installation is 20" (50.8cm) of horizontal run, in addition to the 45° offset. In
this case 0" rise is acceptable when using rigid venting. When using fl exible venting, it is required to maintain a 6"
(152mm) rise. See illustrations below for more information.
12" (30.5cm)
minimum
to grade
FLEXIBLE VENTING RIGID VENTING
Required Rise
Rear Vent
Corner
Rigid Venting 0"
Flexible Venting 6" (152mm)