Napoleon GSS48ST OUTDOOR GAS FIREPLACE

User Manual - Page 16

For GSS48ST. Also, The document are for others Napoleon models: GSS48

PDF File Manual, 40 pages, Read Online | Download pdf file

GSS48ST photo
Loading ...
Loading ...
Loading ...
16
www.napoleon.com
N415-0346-AU FEB 23.21
Natural Gas Hook-Up
The gas appliance is designed to operate with natural gas or propane gas. The piping up to the appliance
is the responsibility of the installer. A exible metal connector of 1/2 inch male is included to simplify the
installaon of the appliance. Ensure that the exible connector is protected from damage. The gas supply
pipe must be suciently sized to supply the MJ/h specied on the rang plate, based on the length of
the piping run.
The Natural Gas regulator supplied with the appliance must be connected to the gas connecon inlet.
Purge the gas supply line of any trapped air prior to the rst ring of the appliance.
WARNING!
Risk of re, explosion or asphyxiaon, ensure there are no ignion sources such as sparks or open
ames.
The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the appliance.
The gas er must test the operaon of the appliance before leaving.
All gas connecons must be contained within the appliance when complete.
High pressure will damage the valve, disconnect gas supply piping before tesng gas line at test
pressures above 1/2 psig.
Leak test all the connecons by brushing on a soap and water soluon. These connecons can be
accessed by removing the burner. (See burner removal instrucons.)
NG REGULATOR 1.00 kPa
Gas Hook-Up Instrucons
GAS CONNECTION
!
Loading ...
Loading ...
Loading ...