10
www.napoleon.com
N415-0346-AU FEB 23.21
Minimum Enclosure Clearances
WARNING! Use only non-combusble materials (cered to ASTM E-136) such as steel studs,
cement board, ceramic le, marble, paint etc. When adding nishing materials to the appliance. Do
not use wood or drywall.
WARNING! You must have clear and easy access to the on/o valve AFTER the appliance is installed
and connected to the gas supply in order to safely turn o the burner.
GSS48 (ONE SIDED)
6” (152mm)
(Minimum
clearance to
combusbles)
1 1/2”
(38mm)
All material in shaded
area must be Non
Combusble. (including
framing, sheeng and
nishing materials).
Cered to ASTM E-136
NON COMBUSTIBLE
36”
(914mm)
minimum
to ceiling.
6”
(152mm)
minimum to
oor
1/2”(13mm)
Cement Board
6”(152mm)
Steel Stud
NOTE! Ensure top of cabinet is closed to
prevent rain and debris from falling on top of
the appliance.
6”
(152mm)
Nailing Tabs (4 per side)
50 3/4” (1289mm)
(Including 1/8” (3mm)
clearance per side)
Gas and electrical lines protude from the
boom of the appliance located on the
right side.
NON COMBUSTIBLE
All material in shaded
area must be Non
Combusble. (including
framing, sheeng and
nishing materials).
Cered to ASTM E-136
36”
(914mm)
minimum
to ceiling.
24 3/4” (629mm)
Including 1/8”
(3mm) clearance
per side.
60 3/4”
(1543mm)
minimum
to ceiling.
6”
(152mm)
6”
(152mm)
6”
(152mm)
minimum to
oor
!
!