Dimplex ECS250HP40A-580 250L A-Class Heat Pump Cylinder With Buffer

User Manual - Page 30

For ECS250HP40A-580.

PDF File Manual, 44 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Technical Data
A Class HP
Installation a
nd User Instructions R02583
-6 09/15
Page
30
A Class Heat Pump Cylinder Range Product Features
Actual capacity [L]
144 + 40
180 + 40
207+40
247 + 40
Materials
- inner cylinder
Duplex stainless steel LDX2101
- outer cylinder
HIPS
- inlet/outlet
Stainless steel
- coils
Stainless steel
- insulation
60mm PU foam (GWP=1, ODP=0)
Maximum operating conditions
- potable water temperature
70°C
- heating water temperature
95°C
- operating pressure
3 bar
- max. design pressure
6 bar
Cold water supply
- minimum dynamic pressure
1.5 bar
- maximum static pressure
12 bar
- minimum flow rate
15 l/min
Connections
- cold water inlet
22mm stainless steel
- hot water outlet
22mm stainless steel
- coil flow and return
28mm stainless steel
Coil specification
- heat pump coil surface area [m²]
2.2
- HX performance heat pump coil [kW]
46
43
42
- max. working pres. [Bar]
3
Immersion heater
1 ¾ F BSP 3kW @ 240 V
Thermostatic control
- direct input
Rod stat with variable and high limit cut out
- indirect input
Rod stat with variable and high limit cut out
Safety components
- pressure reducing valve and strainer
3 bar
- expansion relief valve
6 bar
- temperature and pressure relief valve
½” 7 bar/90°C
- factory pressure test
12 bar
Other features
Over 60% in volume from recycled materials#
Surface mounted sensor devices for compatibility and
ease of maintenance
Guarantee (*)
- inner cylinder
25 yrs.
- immersion heaters
2 yrs. - excluding the effects of lime scale or
other water borne contaminants
- other components
2 yrs. - excluding expansion vessel membrane pressure
Table 5: A Class Heat Pump Cylinder Product Fiche and Features
# Not including insulation
(*) subject to terms and conditions
Loading ...
Loading ...
Loading ...