Installation
*INSTALLATION*
25
Aligning the installation niche
The building-in niche must be carefully
aligned using a spirit level before the
refrigeration appliance is installed. The
niche corners must be at 90° angles to
each other, otherwise the cabinet front
will not sit straight on all 4corners of
the building-in niche.
Checking the installation niche
Check the installation dimensions
(see “Installation – Installation
dimensions”).
Check the position of the electrical
connection. The length of the power
cord is 9' 10" (3m).
The electrical socket must not be
concealed behind the appliance and
must be easily accessible in an
emergency.
Check the surroundings for possible
collisions (see “Installation –
Dimensions with appliance door
open”).
Only install the refrigeration appliance
in stable, solid building-in niches,
positioned on an even and level floor.
Also check the building-in niche for
the following criteria:
- The side panels of the installation
niche must be even.
- The surrounding walls of the
installation niche must be at least
5/8” (16mm) thick.
- The surrounding walls must be
securely fixed to the floor or wall.
- Shortened side walls must be at least
4" (100mm) deep.